Checklist · Plant & Equipment Inspections

Mobile Scaffold Tower Inspection Checklist

Inspection checklist for aluminium mobile scaffold towers, completed after erection, before each shift, after relocation and after any event that could affect stability. Covers castors, frames, bracing, platforms, guardrails, access and stability limits.

34 checklist items

Checklist Items

ItemPass / YesFail / No
TOWER DETAILS
Date of Inspection
Site / Location
Tower Make, Model & ID
Platform Height (m)
Inspection Reason (after erection / pre-shift / after relocation / after incident or weather)
Inspector Name and Competency
BASE & CASTORS
Ground or floor is level, firm and free of holes, pits, penetrations and debrisPassFail
All castors locked (brakes on) and swivel locks engaged where fittedPassFail
Castor wheels and stems undamaged and fully engaged in the legsPassFail
Adjustable legs within manufacturer's maximum extensionPassFail
Outriggers / stabilisers fitted where required by the manufacturer for this heightPassFail
FRAMES & BRACING
Tower built to manufacturer's instruction manual for this configurationPassFail
Frames plumb and not twistedPassFail
Frame interlock clips / locking pins engaged at every jointPassFail
Horizontal and diagonal braces in the correct positions with hooks fully lockedPassFail
No bent, cracked, dented or corroded components; no mixed brands of componentsPassFail
Height-to-base ratio within the manufacturer's limit for indoor / outdoor usePassFail
PLATFORMS & EDGE PROTECTION
Working platform fully decked; platform wind locks engagedPassFail
Trapdoor platform opens and closes correctlyPassFail
Guardrails and mid-rails fitted on all sides of the working platformPassFail
Toe boards fitted on all sides of the working platformPassFail
No ladders, steps or boxes used on the platform to gain extra heightPassFail
ACCESS
Internal ladder or stairway access only (no climbing on the outside of frames)PassFail
Access rungs undamaged and clear of mud or greasePassFail
SURROUNDINGS & USE
Clearance from overhead powerlines meets the required approach distance (check with network operator)PassFail
Clear of trafficable areas, or barricaded from vehicles and pedestriansPassFail
Safe working load of platform displayed and not exceededPassFail
Not used in high winds or with sheeting / signage attached (wind loading)PassFail
Tower not moved with persons or materials on the platformPassFail
Scaffold tag completed and displayed at access pointPassFail
RESULT & SIGN-OFF
Defects found and action taken
Tower safe to use (if No, tag "Do Not Use" and restrict access)YesNo
Next Inspection Due
Inspector Signature