Checklist · Building & Property

Roof Anchor Point Inspection Checklist

Inspection checklist for permanently installed roof anchor points, static lines and roof safety systems used for harness-based work at height. Covers anchor identification, compliance plates, fixings, corrosion, roof structure and documentation.

33 checklist items

Checklist Items

ItemPass / YesFail / No
INSPECTION DETAILS
Date of Inspection
Building Name / Address
Roof Area / Anchor Layout Plan Reference
Anchor or System ID(s) Inspected
System Type (single-point anchors / static line / rail / ladder bracket)
Inspector Name and Height Safety Competency
DOCUMENTATION
Roof anchor layout plan displayed at roof access pointPassFail
Installation certificate and manufacturer's instructions availablePassFail
Date of Last Periodic Inspection
Inspection interval follows AS/NZS 1891.4 and the manufacturer's instructions; current inspection not overduePassFail
IDENTIFICATION & TAGS
Each anchor has a compliance tag / plate showing rating, installer and next inspection datePassFail
Tags legible and currentPassFail
Anchor numbers match the layout planPassFail
ANCHOR CONDITION
Anchor eye / ring not bent, cracked, deformed or showing signs of a fall arrest loadPassFail
Energy absorber indicator not deployed (where fitted)PassFail
No corrosion, pitting or rust staining on anchor, bolts or base platePassFail
All fixings present, tight and of the type specified by the manufacturerPassFail
Anchor does not move, rotate or lift when tested by handPassFail
Penetration through roof sheeting sealed; no water leaks around the anchorPassFail
STATIC LINES & RAILS (IF FITTED)
Cable or rail: no fraying, kinks, broken wires or corrosionPassFail
Line tension within manufacturer's rangePassFail
Intermediate brackets, end anchors and tensioner securePassFail
Travelling devices / shuttles run freely and are the system-compatible typePassFail
ROOF STRUCTURE & ACCESS
Roof sheeting and purlins around the anchor sound (no rust-through or loose fixings)PassFail
Fragile roof areas and skylights near anchors marked or protectedPassFail
Anchor positions allow work without pendulum or swing-fall risk to the roof edgePassFail
Safe access to the roof (fixed ladder, hatch or walkway) in good conditionPassFail
RESULT & SIGN-OFF
Defects found and action taken
Defective anchors tagged "Do Not Use" and removed from the layout plan until repairedYesNo
System compliant and fit for useYesNo
Next Inspection Due
Inspector Signature
Building Owner / Manager Signature