Daily Plant Prestarts

Boom Lift (Knuckle / Telescopic EWP) Pre-Start Checklist

Daily pre-start inspection for self-propelled and trailer-mounted boom lifts covering the boom, jib, turntable, platform, harness anchor points, tilt alarm and emergency lowering. Completed by the operator before each shift.

43 checklist items

Download this template

Checklist Items

ItemPass / YesFail / No
MACHINE & OPERATOR DETAILS
Date___________________________
Plant ID / Serial Number___________________________
Make, Model & Working Height___________________________
Operator Name___________________________
High Risk Work Licence Number (WP required for boom length 11 m or more)___________________________
Hour Meter Reading___________________________
POWER & FLUIDS
Fuel level or battery charge adequate for shiftPass ☐Fail ☐
Engine oil and coolant levels adequate (engine units)Pass ☐Fail ☐
Hydraulic oil level adequatePass ☐Fail ☐
No hydraulic, fuel or battery leaksPass ☐Fail ☐
CHASSIS & TURNTABLE
Tyres / wheels: no damage, wheel nuts securePass ☐Fail ☐
Outriggers / stabilisers (if fitted): pads and interlocks operatePass ☐Fail ☐
Turntable bearing and bolts: no visible play or damagePass ☐Fail ☐
Counterweight secure, no damagePass ☐Fail ☐
Turntable lock / slew pin released for operationPass ☐Fail ☐
BOOM & JIB
Boom sections and knuckle: no cracks, dents or weld damagePass ☐Fail ☐
Jib and rotator: no damage, operate smoothlyPass ☐Fail ☐
Wear pads, chains and cables (where visible) serviceablePass ☐Fail ☐
Hydraulic hoses: no chafing, leaks or damagePass ☐Fail ☐
Pins and retainers all in placePass ☐Fail ☐
PLATFORM / BASKET
Platform floor, rails and mid-rails undamagedPass ☐Fail ☐
Entry gate / chain self-closes and latchesPass ☐Fail ☐
Harness anchor points: present, undamaged, labelledPass ☐Fail ☐
Rated load plate (persons and kg) legiblePass ☐Fail ☐
Platform controls labelled, guarded and return to neutralPass ☐Fail ☐
Secondary guarding / anti-entrapment device operational (if fitted)Pass ☐Fail ☐
SAFETY DEVICES & FUNCTION TESTS
Ground controls: all functions tested from ground stationPass ☐Fail ☐
Platform controls: all functions tested, foot switch / enable operatesPass ☐Fail ☐
Emergency stops at ground and platform functionalPass ☐Fail ☐
Tilt alarm / cut-out operationalPass ☐Fail ☐
Platform overload sensing operational (if fitted)Pass ☐Fail ☐
Emergency / auxiliary lowering system testedPass ☐Fail ☐
Travel alarm, horn and beacon operationalPass ☐Fail ☐
Manual and decals on machine and legiblePass ☐Fail ☐
SITE CHECKS
Ground firm and level; no pits, trenches or soft spotsYes ☐No ☐
Overhead hazards and powerlines identifiedYes ☐No ☐
Rescue plan in place for stranded or injured operatorYes ☐No ☐
Operator and occupants wearing harness with short lanyard clipped to anchorYes ☐No ☐
DEFECTS & SIGN-OFF
Defects found (describe or write "None")___________________________
Defects reported to supervisorYes ☐No ☐
Machine fit for operationYes ☐No ☐
Operator Signature___________________________
Supervisor Signature___________________________

Download this template

Run checklists digitally with WorkSignals

Complete this checklist on your phone, capture photos of defects, and generate instant reports — no paper required.

Try WorkSignals free